TW-228 Toy Chest Lid Durability Tester: Test Principle Operation Guidelines and Safety Notes

Toy Chest Lid Durability Tester TW 228

Purpose of equipment

We proudly launch the high-performance Toy Box Lid Durability Tester, a professional quality testing device designed for durability and safety evaluation of children’s toy box lids and hinge structures. Compliant with global toy safety standards, this instrument delivers accurate and repeatable cyclic test data for manufacturers and third-party labs to eliminate structural safety risks of kids’ storage boxes caused by long-term opening and closing.
 

Featuring intelligent digital control, high-precision driving and ±0.5% low test error, the tester supports real-time data display, automatic counting and one-click report export. Built with anti-vibration structure and overload protection, it ensures stable, low-noise and long-duration operation in factory and laboratory environments.

Suitable for wooden, plastic and covered children’s toy boxes, this tester is essential quality control equipment for toy manufacturers and testing institutions. It helps enterprises meet global safety certification requirements, reduce safety risks and improve market competitiveness.

We will continue to optimize professional testing equipment to deliver reliable industry solutions and safeguard children’s product quality and safety.

Operating steps

1. Pre-operation confirmation items:
    ① Confirm that the power supply meets the requirements.
    ② Confirm that the air source meets the  requirements.
    ③ Turn on the power supply, connect the air source, and turn on the power switch.
    ④ Confirm that the cylinder is in the retracted position.
2. Installation of the test piece:
    ① Press the retract button of the cylinder to make it retract to the position, place the toy box sample at an appropriate position below the cylinder, open the lid to the calibrated opening angle, and fix it on the lid with a fixture.
    ② Slowly press the push button of the cylinder to make it push out to the position where the toy box lid just closes, adjust the cylinder push-out sensor with a screwdriver until the sensor light turns on and then lock the screw.
    ③ Press the retract button of the cylinder to make it retract to the position.
3. Start the test:
    ① Reset the current value of the counter to zero, and set the test times according to the standard to 7000 times (enter the number of tests by pressing the counter key, select the test number with the key, set it and wait for 10 seconds for the machine to automatically complete).
    ② Press the Start button to start the test. When the set number of tests is reached, the machine will automatically stop.
    ③ Release the fixture and remove the sample.
    ④ Test completed.